On 12/01/2022 I Checked a walk-in freezer and found that it was low on Freon. I completed a leak check and found a leak on the copper line. I repaired the leak and Added 5 lbs. of R404a. I Waited until freezer had dropped down to the set point in Frisco Texas. Near Lebanon rd…
Read more
Replaced a Bad Condenser Fan Motor
On 11/30/2022 We replaced a bad condenser fan motor and removed an unnecessary defrost time that had also failed in Haslet Texas. Near Santa Fe Court Haslet, Texas 76052 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3540]
Read more
Replaced Evaporator Fan Motor
On 11/28/2022 Checked walk-in cooler. Found that the coil was ice up. Also had one bad evaporator fan motor. Powered unit down and removed ice with hot water. Acquired motor. Replaced motor. While melting ice on the coil found that the drain was not draining due to the drain line was ran uphill. Fixed drain…
Read more
Added a Down Spout Extension for UV Protection
On 11/23/2022 we added a down spout extension for UV protection on rooftop piping in Saginaw Texas. Near Bailey Boswell Rd Saginaw, Texas 76179 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3540]
Read more