6/13/2023 Found Supera single door freezer at -4 on arrival. Customer stated it got to -14. Set point at -8 with 6 degree differential. Reset controls to 2 degrees. Checked drain heater, working. Checked evap and condenser, working. Sure low setting caused insulation to be saturated and frozen. Insulation now back to correct state. Gaskets…
Read more
Solenoid Coil was a 208V Coil and the System Required a 120
6/8/2023 I noticed the solenoid coil was a 208V coil and the system required a 120. I went to go get the replacement and installed it and confirmed the system was working as it should in Plano Texas. Near W Park Blvd Plano, Texas 75093 Check out the Areas We Serve and jobs we are…
Read more
Unit Had a Blown Gear Motor Fuse
6/5/2023 Unit had a blown gear motor fuse took me some time to find a replacement. I replaced the fuse. I pulled an amp draw on all electrical components and found them well within specs in Irving Texas. Near N Union Bower Rd Irving, Texas 75061 Check out the Areas We Serve and jobs we…
Read more