Reach in cooler making noise and not holding temp. Found built up in drain pan and fan motor unable to spin due to ice. Cleared drain with nitro installed drain pan tabs to help with preventing future clogging on 8/12/24 in Dallas Texas. Near Lemmon Ave Dallas, TX 75219 Check out the Areas We Serve…
Read moreIce Machine Door Switch not Activating
Ice machine door switch not activating due too door not properly placed after customer cleaned unit. Adjusted door and door switch, started unit up verified operation on 8/11/24 in Frisco Texas. Near Main St Frisco, TX 75033 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3540]
Read moreRemoved Existing Suction Line Drier
Removed existing suction line drier, brazed 1 coupling with a 2 ft long straight 3/4 copper tube and Pulled vacuum to under 500 microns. Charged system with 15 pounds of 404A. Watched 3 batches of ice drop on 8/9/24 in Tyler Texas. Near Towne Crossing Boulevard Mesquite, TX 75150 Check out the Areas We Serve…
Read moreReach in Cooler had a Dirty Condenser Coil
Reach in cooler had a dirty condenser coil as well as a scrambled PCB board due to infestation, unit comes on and off but not reaching set temp. I managed to clean coils and clean board with contact cleaner. Started unit and unit reaching colder temps on 8/8/24 in Tyler Texas. Near S Broadway Ave…