Case Cooler Low on Freon due to leaking packing nut on king valve and TXV wide open. Repaired leak, cleaned coil and charged unit with 6lbs of r449a and adjusted TXV to proper superheat on 9/16/24 in Hutchins Texas. Near I-45 Hutchins, TX 75141 Check out the Areas We Serve and jobs we are doing…
Read more
Replaced Faulty Motor on Freezer
Replaced faulty motor on Freezer with a new one and also charged unit with 2.7 lbs. of r404a to make repairs on 9/13/24 in Dallas Texas. Near North Westmoreland Road Dallas, Texas 75211 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3540]
Read more
Found Bad Start Capacitor
Found Bad Start Capacitor. Managed to get one from truck stock 145-175uf started unit up verified operation all ops normal at this time on 9/12/24 in Sulphur Springs Texas. Near Main Street Dallas, TX 75226 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3540]
Read more
Installing Ice Machine
Installing ice machine. Removed old unit and installed new one. Brazed in line set pulled vacuum to 400 microns started unit up verified operation all ops normal at this time on 9/11/24 in Sulphur Springs Texas. Near Hillcrest Dr South, Sulphur Springs, TX 75482 Check out the Areas We Serve and jobs we are doing…
Read more