Glycol chiller had bad capacitor. Replaced capacitor and installed customer provided discharge bypass valve on 8/20/24 in McKinney Texas. Near Majesty Drive, Dallas, TX 75247 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3540]
Read more
Hot Well Not Heating
Hot well not heating. Located hot well tested voltage found no power. Traced power back to a sub panel found breaker tripped rest breaker and unit heating on 8/18/24 in McKinney Texas. Near West University Drive McKinney, TX 75070 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3540]
Read more
Found High Head Pressure Alarm
Found high head pressure alarm. Pulled condenser screen and found it was totally clogged. Cleaned and put back in place. No further issues at this time on 8/16/24 in Plano Texas. Near West Parker Road Plano, TX 75023 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3540]
Read more
Two Drawer Line Cooler Icing Up
Two drawer line cooler icing up. Performed diagnostics and found thermostat was set at its coldest point causing unit to ice up. Adjusted thermostat on 8/15/24 in Garland Texas. Near Broadway Blvd Garland, TX 75043 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3540]
Read more