Replaced the Expansion Valve and Confirmed

On 6/15/2023 I cycled the system when I arrived and found a high head pressure. I cleaned the condenser by blowing it out with nitrogen. The head pressure came down but the over all pressure was low. I added some refrigerant and cycled the system multiple times only to find it was making ice on the bottom half of the evap plate, replaced the expansion valve and confirmed 3 batch drops in Kennedale Texas.