On 7/26/2023 pumped down units and started replacing expansion valves. Had to move product around to get to valves but after replacing pulled a deep vacuum and started working on the big cooler. In the big cooler I adjusted fan speed for one motor and got temp to start dropping as one of the fans…
Read moreCondenser Motor No Good
On 7/25/2023 Diagnosed unit found condenser motor no good and proceeded to replace after replacing turned unit and watched it reach temp in Carrollton Texas. Near Meadow Dr Carrollton, Texas 75007 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3540]
Read moreCoils Were Coated With Grease
On 7/24/2023 Removed panels, checked unit... coils were coated with grease. Cleaned with coil cleaner. Dried and checked set temp. Re-assembled in Denton Texas. Near East Oak Street Denton, Texas 76201 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3540]
Read moreNoticed Oil on Suction Service Valve
On 7/21/2023 Arrived and checked unit immediately noticed oil on suction service valve by compressor and sight glass was flashing found leak on suction side the valve was slightly open and the cap on valve is like aluminum and was cracked leaking I put new caps on and closed valve tightly....box was at 55 when…