On 7/13/2023 Found the system at around 45-47* and in defrost. I tapped into the system and the pressures looked okay but a little low on the suction side. I tried adjusting the superheat but the system was low on gas. I found a leak under the access port where the brass meets the copper.…
Read moreRemoved and Replaced Compressor and Rewired
On 7/12/2023 removed and replaced compressor and rewired also pulled a good vacuum and added one-pound r134a and left let run for ten minutes. Pressures when I left were at 20.3 on the low and 181 on the high unit was in operation in Dallas Texas. Near Colgate Avenue Dallas, Texas 75225 Check out the…
Read moreIce Machine Board Burnt Out
On 7/11/2023 Ice machine board burnt out removed and replaced and verified harvest of ice in Irving Texas. Near N Belt Line Rd Irving, Texas 75062 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3540]
Read moreThickness Sensor Was Turned Up
On 7/6/2023 I noticed the ice thickness sensor was turned up and away from the evaporator. I repositioned it properly and started the cycle. I ran it through 3 cycles adjusting the sensor to make the ice properly. Unit is working and making ice as it should in Wylie Texas. Near Inspiration Blvd Wylie, Texas…