On 1/9/2023 Checked beverage cooler. Found that the start relay was burned up. Also found that the start capacitor went bad. Replaced both start relay and start capacitor. Also fixed all burned wires. Checked operation. Compressor amping at 8.8 amps in Dallas Texas. Near GREENVILLE AVE Unit 205 Dallas, Texas 75206 Check out the Areas…
Read more
Condenser Coil was Plugged With Dust
On 1/6/2023 Checked break room refrigerator. Found that compressor was hot to the touch due to it being off on internal overload. This happened because the condenser coil was plugged with dust. Brushed dust off the coil and blew it out with nitrogen. Put a bag of ice on top of the compressor to cool…
Read more
Replaced Reach in Cooler Starting Components
On 11/4/2023 Checked reach in cooler. Found that condenser fan motor running but the compressor was not. Checked compression with mega ohm meter, compressor is good but it’s on its way out. Replaced reach in cooler starting components. Checked operation. Compressor came on and is cooling down the box in Frisco Texas. Near Frisco St…
Read more
Found that Everything in the Inside Fell Apart like the Unit was Roughly Handled
On 1/3/2022 Checked reach in freezer. Found that everything in the inside fell apart like the unit was roughly handled. Mounted the evaporator coil back up to case ceiling. Fixed sensor on coil due to the wiring breaking. Once everything was back together tested operation. Found that one motor was bad and 2 fan blades…
Read more