Discharge ROTOLOK Fitting had Vibrated Loose

On 5/23/2023 started leak checking the Evaporator with electronic detector, no hits inside walk in, proceeded to condenser and found the discharge ROTOLOK fitting had vibrated loose and was leaking, I tightened the fitting and stopped the leak, I did find a small leak on the txv valve pick up screen that I tightened also, no further leaks found. Charged the system with 4lbs of R404A. Watched unit come down to proper temperature in Garland Texas.