On 4/26/2023 found unit has the sanitize light on, i ran the unit through its clean cycle to get the light off, once the clean light was off i tested all other proper operations, found the unit had a leak on the discharge side, the high pressure switch was leaking and found the water level…
Read moreCleaned the Dirty Condenser Coil
On 4/24/2023 Upon arrival I found unit completely empty, I found the coil frozen up and cleaned the dirty condenser coil. I ran the unit through defrost a couple times to clear off ice, once cleared I tested units heaters along with the time of defrost, unit was left open and caused evaporator to freeze…
Read moreSchrader Core on the Discharge was Leaking
On 4/20/2023 Upon arrival I found the unit at 55 degrees, I found the unit was low on refrigerant, causing the issues, upon further investigation I found the Schrader core on the discharge was leaking. I replaced the core and installed a steel cap to ensure no further leaks will occur on the said line.…
Read moreFound the Walk In Cooler Over Charged
On 4/18/2023 Found the walk in cooler over charged. The walk in freezer needs a liquid line filter drier, checked all operations, no further issues found. Wic is working as it should in Red Oak Texas. Near South Main Street Red Oak, Texas 75154 Check out the Areas We Serve and jobs we are doing…