Replaced door handle on drink cooler on 10/2/2023 in Fort Worth Texas. Near Hulen St Fort Worth, Texas 76107 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3540]
Read more
Found the water valve faulty
Found the water valve faulty and the water pump faulty on 8/31/2023 and I replaced both parts and verified harvest of ice three times in Addison Texas. Near Addison Cir Addison, Texas 75001 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3540]
Read more
Leak Detector Went Off as Soon as I Stepped In The Room
On 8/28/2023 I started leak checking the evap and the leak detector went off as soon as I stepped in the room. I opened the main door as well as a couple glass doors to let it air out. I started another leak detection and found that there was a core cap missing and some…
Read more
unit is run by dixell controller
On 7/27/2023 Arrived and found unit iced up...unit is run by Dixell controller I unplugged controller and compressor was still running come to find that someone was here prior to us and wired compressor direct and the controller was not working either .... I rewired everything as it should go and verified defrost was cycling…
Read more